dc.contributor.author | Ören, Tuğba | |
dc.contributor.author | Anık, Ülkü | |
dc.date.accessioned | 2020-11-20T14:52:27Z | |
dc.date.available | 2020-11-20T14:52:27Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 0263-2241 | |
dc.identifier.issn | 1873-412X | |
dc.identifier.uri | https://doi.org/10.1016/j.measurement.2017.04.031 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12809/1902 | |
dc.description | WOS: 000403128800004 | en_US |
dc.description.abstract | In the present study, simple and sensitive voltammetric determination of caffeine was carried out by using a gold nanoparticle-glassy carbon paste composite electrode (AuNP-GCPE) in 3.2 mM H2SO4 (pH 2.5). The effects of supporting electrolyte, pH and AuNP amount on caffeine peak current were investigated. After the optimization of experimental parameters, analytical characteristics of AuNP-GCPE were examined and two linear ranges were obtained between 25-150 mu M and 200-1000 mu M with limit of detection values of 0.96 mu M and 4.90 mu M, respectively. Relative standard deviation for 50 mu M caffeine was also calculated as 7.52% (n = 3). In order to evaluate the analytical performance of AuNP-GCPE, caffeine contents of various brands of cola samples were measured and compared with the results obtained by UV-Vis spectrometer. The obtained results by using the proposed composite electrode are in accordance with the caffeine contents that manufacturers claimed compared to UV-Vis. This composite electrode which utilizes the catalytic effect of AuNP with the simple preparation of GCPE, offers a fast and sensitive determination of caffeine in beverages as a practical application. (C) 2017 Elsevier Ltd. All rights reserved. | en_US |
dc.item-language.iso | eng | en_US |
dc.publisher | Elsevier Sci Ltd | en_US |
dc.item-rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Caffeine | en_US |
dc.subject | Aunp | en_US |
dc.subject | Composite Electrode | en_US |
dc.subject | Glassy Carbon Paste Electrode | en_US |
dc.title | Voltammetric determination of caffeine by using gold nanoparticle-glassy carbon paste composite electrode | en_US |
dc.item-type | article | en_US |
dc.contributor.department | MÜ, Fen Fakültesi, Kimya Bölümü | en_US |
dc.contributor.authorID | 0000-0003-3680-5743 | |
dc.contributor.authorID | 0000-0002-3607-7208 | |
dc.contributor.institutionauthor | Anık, Ülkü | |
dc.contributor.institutionauthor | Ören, Tuğba | |
dc.identifier.doi | 10.1016/j.measurement.2017.04.031 | |
dc.identifier.volume | 106 | en_US |
dc.identifier.startpage | 26 | en_US |
dc.identifier.endpage | 30 | en_US |
dc.relation.journal | Measurement | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |