Basit öğe kaydını göster

dc.contributor.authorAltuntaş, Derya Bal
dc.contributor.authorTepeli, Yudum
dc.contributor.authorAnık, Ülkü
dc.date.accessioned2020-11-20T15:02:04Z
dc.date.available2020-11-20T15:02:04Z
dc.date.issued2016
dc.identifier.issn2053-1583
dc.identifier.urihttps://doi.org/10.1088/2053-1583/3/3/034001
dc.identifier.urihttps://hdl.handle.net/20.500.12809/2370
dc.descriptionWOS: 000397826400001en_US
dc.description.abstractGraphene sheets and three different graphene-metallic nanocomposites including graphene-copper (graphene-Cu), graphene-nickel (graphene-Ni) and graphene-platinum (graphene-Pt) were prepared and characterized in the first place. Then the electrochemical performances of these nanocomposites were tested in glucose biosensor transducers, which were formed by combining these metallic nanocomposites with glucose oxidase enzyme and glassy carbon paste electrode (GCPE). This is the first work that includes the usage of these graphene-Me nanocomposites as a part of glucose biosensor transducer. Fabricated amperometric biosensors linear ranges were obtained as follow: For the plain graphene, the linear range was found in the concentration range between 50 mu Mand 800 mu Mwith the RSD (n= 3 for 50 mu M glucose) value of 12.86% and LOD value of 7.2 mu M. For graphene-Pt modified glucose biosensor, the linear range was between 10 mu M and 600 mu M with the RSD (n= 3 for 50 mu M glucose) value of 3.45% and LOD value of 3.06 mu M. In the case of graphene-Ni modified glucose biosensor, the values were 25 mu M to 600 mu M with the RSD (n= 3 for 50 mu M glucose) value of 8.76% and LOD value of 24.71 mu M and for graphene-Cu modified glucose biosensor linear range was 25 mu M to 400 mu M with the RSD (n= 3 for 50 mu M glucose) value of 3.93% and LOD value of 2.87 mu M.en_US
dc.item-language.isoengen_US
dc.publisherIop Publishing Ltden_US
dc.item-rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGraphene-Pten_US
dc.subjectGraphene-Nien_US
dc.subjectGraphene-Cuen_US
dc.subjectNanocompositesen_US
dc.subjectGlucose Biosensoren_US
dc.titleGraphene-metallic nanocomposites as modifiers in electrochemical glucose biosensor transducersen_US
dc.item-typearticleen_US
dc.contributor.departmentMÜ, Fen Fakültesi, Kimya Bölümüen_US
dc.contributor.authorID0000-0002-3607-7208
dc.contributor.authorID0000-0002-4717-7933
dc.contributor.institutionauthorAltuntaş, Derya Bal
dc.contributor.institutionauthorTepeli, Yudum
dc.contributor.institutionauthorAnık, Ülkü
dc.identifier.doi10.1088/2053-1583/3/3/034001
dc.identifier.volume3en_US
dc.identifier.issue3en_US
dc.relation.journal2D Materialsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster